Highlights
- •
Swabs made of cotton, flocked nylon and foam gave equivalent DNA recoveries for smooth/non-absorbing surfaces.
- •
Applying a 60º angle and rotating the swab during sampling improved DNA yield for cotton swabs.
- •
Increased volume of wetting agent was favourable when swabbing on wood.
- •
The developed sampling protocols improved DNA recovery for wood and lowered person-to-person variation for ridged plastic.
- •
Increased surface complexity led to larger differences between swabs as well as between swabbing techniques.